Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
4.
Int J Cardiovasc Imaging ; 39(9): 1825-1837, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37405610

RESUMO

Accurate determination of coronary reference size is essential for optimal stent selection and evaluation of stent expansion during percutaneous coronary intervention (PCI). Several approaches for reference size estimation have been published with no universal agreement. The aim of this study was to investigate if potential differences in coronary reference size estimation lead to differences in stent and balloon selection and in detection of stent under expansion. Definitions for coronary reference size estimation, stent size selection, and stent expansion were identified in 17 randomized controlled trials. The identified methods were applied in a population of 32 clinical cases. Reference size estimates ranged up to 1.35mm, and indicated nominal stent size ranged up to 1.0 mm in the same case depending on method. Mean relative stent expansion ranged from 54±12% to mean 100±29% depending on the applied reference method. Choice of method for reference size estimation using intravascular imaging may influence stent selection and greatly affects evaluation of post-PCI stent expansion.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Stents , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
5.
Open Heart ; 10(2)2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37487656

RESUMO

INTRODUCTION: Current guideline recommend functional imaging for myocardial ischaemia if coronary CT angiography (CTA) has shown coronary artery disease (CAD) of uncertain functional significance. However, diagnostic accuracy of selective myocardial perfusion imaging after coronary CTA is currently unclear. The Danish study of Non-Invasive testing in Coronary Artery Disease 3 trial is designed to evaluate head to head the diagnostic accuracy of myocardial perfusion imaging with positron emission tomography (PET) using the tracers 82Rubidium (82Rb-PET) compared with oxygen-15 labelled water PET (15O-water-PET) in patients with symptoms of obstructive CAD and a coronary CT scan with suspected obstructive CAD. METHODS AND ANALYSIS: This prospective, multicentre, cross-sectional study will include approximately 1000 symptomatic patients without previous CAD. Patients are included after referral to coronary CTA. All patients undergo a structured interview and blood is sampled for genetic and proteomic analysis and a coronary CTA. Patients with possible obstructive CAD at coronary CTA are examined with both 82Rb-PET, 15O-water-PET and invasive coronary angiography with three-vessel fractional flow reserve and thermodilution measurements of coronary flow reserve. After enrolment, patients are followed with Seattle Angina Questionnaires and follow-up PET scans in patients with an initially abnormal PET scan and for cardiovascular events in 10 years. ETHICS AND DISSEMINATION: Ethical approval was obtained from Danish regional committee on health research ethics. Written informed consent will be provided by all study participants. Results of this study will be disseminated via articles in international peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT04707859.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Transversais , Dinamarca , Estudos Prospectivos , Proteômica , Água , Estudos Multicêntricos como Assunto
6.
JACC Cardiovasc Imaging ; 16(10): 1321-1331, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37052562

RESUMO

BACKGROUND: Fractional flow reserve (FFR) derived from invasive coronary angiography (QFR) is promising for evaluation of intermediate coronary artery stenosis. OBJECTIVES: The authors aimed to compare the diagnostic performance of QFR and the guideline-recommended invasive FFR using 82Rubidium positron emission tomography (82Rb-PET) myocardial perfusion imaging as reference standard. METHODS: This is a prospective, observational study of symptomatic patients with suspected obstructive coronary artery disease on coronary computed tomography angiography (≥50% diameter stenosis in ≥1 vessel). All patients were referred to 82Rb-PET and invasive coronary angiography with FFR and QFR assessment of all intermediate (30%-90% diameter stenosis) stenoses. Main analyses included a comparison of the ability of QFR and FFR to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score ≥4 in ≥2 adjacent segments). RESULTS: A total of 250 patients (320 vessels) with indication for invasive physiological assessment were included. The continuous relationship of 82Rb-PET stress myocardial blood flow per 0.10 increase in FFR was +0.14 mL/g/min (95% CI: 0.07-0.21 mL/g/min) and +0.08 mL/g/min (95% CI: 0.02-0.14 mL/g/min) per 0.10 QFR increase. Using 82Rb-PET as reference, QFR and FFR had similar diagnostic performance on both a per-patient level (accuracy: 73%; 95% CI: 67%-79%; vs accuracy: 71%; 95% CI: 64%-78%) and per-vessel level (accuracy: 70%; 95% CI: 64%-75%; vs accuracy: 68%; 95% CI: 62%-73%). The per-vessel feasibility was 84% (95% CI: 80%-88%) for QFR and 88% (95% CI: 85%-92%) for FFR by intention-to-diagnose analysis. CONCLUSIONS: With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis. (DAN-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease; NCT02264717).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Constrição Patológica , Termodiluição , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Tomografia por Emissão de Pósitrons , Índice de Gravidade de Doença
7.
Heart ; 109(16): 1223-1230, 2023 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-36878672

RESUMO

OBJECTIVE: Validation studies of the 2019 European Society of Cardiology pretest probability model (ESC-PTP) for coronary artery disease (CAD) report that 35%-40% of patients have low pretest probability (ESC-PTP 5% to <15%). Acoustic detection of coronary stenoses could potentially improve clinical likelihood stratification. Aims were to (1) investigate the diagnostic performance of an acoustic-based CAD score and (2) study the reclassification potential of a dual likelihood strategy by the ESC-PTP and a CAD score. METHODS: Consecutive patients (n=1683) with stable angina symptoms referred for coronary CT angiography (CTA) underwent heart sound analyses by an acoustic CAD-score device. All patients with ≥50% luminal stenosis in any coronary segment at coronary CTA were referred to investigation with invasive coronary angiography (ICA) with fractional flow reserve (FFR).A predefined CAD-score cut-off ≤20 was used to rule out obstructive CAD. RESULTS: In total, 439 patients (26%) had ≥50% luminal stenosis on coronary CTA. The subsequent ICA with FFR showed obstructive CAD in 199 patients (11.8%). Using the ≤20 CAD-score cut-off for obstructive CAD rule-out, sensitivity was 85.4% (95% CI 79.7 to 90.0), specificity 40.4% (95% CI 37.9 to 42.9), positive predictive value 16.1% (95% CI 13.9 to 18.5) and negative predictive value 95.4% (95% CI 93.4 to 96.9) in all patients. Applying the cut-off in ESC-PTP 5% to <15% patients, 316 patients (48%) were down-classified to very-low likelihood. The obstructive CAD prevalence was 3.5% in this group. CONCLUSION: In a large contemporary cohort of patients with low CAD likelihood, the additional use of an acoustic rule-out device showed a clear potential to downgrade likelihood and could supplement current strategies for likelihood assessment to avoid unnecessary testing. TRIAL REGISTRATION NUMBER: NCT03481712.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Acústica , Angiografia por Tomografia Computadorizada , Constrição Patológica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Valor Preditivo dos Testes , Probabilidade
8.
EuroIntervention ; 18(16): e1358-e1364, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36648404

RESUMO

Quantitative flow ratio (QFR) is a computation of fractional flow reserve (FFR) based on invasive coronary angiographic images. Calculating QFR is less invasive than measuring FFR and may be associated with lower costs. Current evidence supports the call for an adequately powered randomised comparison of QFR and FFR for the evaluation of intermediate coronary stenosis. The aim of the FAVOR III Europe Japan trial is to investigate if a QFR-based diagnostic strategy yields a non-inferior 12-month clinical outcome compared with a standard FFR-guided strategy in the evaluation of patients with intermediary coronary stenosis. FAVOR III Europe Japan is an investigator-initiated, randomised, clinical outcome, non-inferiority trial scheduled to randomise 2,000 patients with either 1) stable angina pectoris and intermediate coronary stenosis, or 2) indications for functional assessment of at least 1 non-culprit lesion after acute myocardial infarction. Up to 40 international centres will randomise patients to either a QFR-based or a standard FFR-based diagnostic strategy. The primary endpoint of major adverse cardiovascular events is a composite of all-cause mortality, any myocardial infarction, and any unplanned coronary revascularisation at 12 months. QFR could emerge as an adenosine- and wire-free alternative to FFR, making the functional evaluation of intermediary coronary stenosis less invasive and more cost-effective.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Vasos Coronários , Europa (Continente) , Japão , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Ensaios Clínicos Controlados Aleatórios como Assunto
9.
Eur Heart J Qual Care Clin Outcomes ; 9(2): 99-108, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36026514

RESUMO

AIMS: We aimed to investigate the relationship between post-percutaneous coronary intervention (PCI) fractional flow reserve (FFR) and clinical outcome using a systematic review with a study-level meta-analysis. METHODS AND RESULTS: MEDLINE, Embase, and CENTRAL were systematically searched for articles with clinical follow-up reporting mean or median final post-PCI FFR. The main outcome was a composite of major adverse cardiac events (MACE) including all-cause death, myocardial infarction (MI), and target vessel revascularization (TVR). Meta-regression analyses were performed on mean post-PCI FFR values. A total of 62 studies with 12 340 patients and 12 923 stented vessels were included, with follow-ups ranging from 1 to 89 months. Post-PCI FFR was not continuously associated with the rate of 1-year MACE or 1-year TVR using meta-regression models accounting for heterogeneous follow-up lengths. For studies comparing high vs. low post-PCI FFR, low post-PCI FFR was associated with high risk ratio for MACE {1.97 [95% confidence interval (CI):1.45-2.67]}, all-cause death [1.59 (95% CI: 1.08-2.34)], MI [3.18 (95% CI: 1.84-5.50)], TVR [2.08 (95% CI: 1.63-2.65)] and angina status [2.50 (95% CI: 1.53-4.06)] using different optimal cut-off values spanning from 0.80 to 0.95. CONCLUSION: We found no clear continuous association between post-PCI FFR and clinical outcomes in this systematic study-level meta-analysis. In a subset of studies investigating binary classification, high post-PCI FFR was associated with a better clinical outcome than low post-PCI FFR.We investigated the relationship between post-percutaneous coronary intervention (PCI) fractional flow reserve (FFR) and rate of major adverse cardiac events (MACE), including all-cause death, myocardial infarction (MI), and target vessel revascularization (TVR), using a systematic review and study-level meta-analysis, pooling 12 340 patients from 62 studies. Mean post-PCI FFR was not continuously associated with a 1-year MACE rate accounting for heterogenous follow-up lengths. Still, the risk ratio favoured high post-PCI FFR for reduced MACE, all-cause death, MI, TVR, and better angina status using different cut-offs.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/etiologia , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Infarto do Miocárdio/etiologia , Angina Pectoris
10.
Coron Artery Dis ; 34(1): 1-10, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36484214

RESUMO

BACKGROUND: Primary percutaneous coronary intervention with implantation of a metallic drug-eluting stent (DES) is the standard treatment for patients presenting with ST-elevation myocardial infarction (STEMI). Implantation of a bioresorbable scaffold (BRS) during STEMI represents a novel strategy without intravascular metal. OBJECTIVE: The aim of the study was to investigate 12-month healing response in an STEMI population after implantation of either the Absorb BRS or Xience DES (Abbott Vascular, USA). METHODS: The present trial was a prospective, randomized, controlled, nonblinded, noninferiority study with planned inclusion of 120 patients with STEMI. Patients were randomly assigned 1:1 to treatment with Absorb BRS or Xience DES. Implantation result and healing response were evaluated by angiography and optical coherence tomography (OCT) at baseline and 12-month follow-up. The primary endpoint was minimum flow area (MFA) assessed at 12 months. Coronary stent healing index (CSHI) was calculated from OCT images. RESULTS: Out of 66 included patients, 58 had follow-up OCT after 12 months, and 49 entered matched analysis. One death occurred in each group; none were stent-related. MFA was 5.13 ± 1.70 mm2 (95% CI, 4.44-5.82) in the BRS group compared with 6.30 ± 2.49 mm2 (95% CI, 5.22-7.37) (P = 0.06) in the DES group. Noninferiority could not be evaluated. CSHI for both groups had a median score of 3. CONCLUSION: The DES group performed numerically better in primary and secondary endpoints, but the CSHI showed good stent healing in both groups.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Everolimo , Estudos Prospectivos , Intervenção Coronária Percutânea/efeitos adversos
11.
Cardiol J ; 30(1): 6-11, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36510793

RESUMO

Percutaneous coronary intervention (PCI) of chronic total occlusions (CTO) in coronary bifurcation lesions (CBL) is undergoing substantial technical progress and standardization, paralleling the evolution of dedicated devices, tools, and techniques. A standard consensus to classify CTO-CBL might be instrumental to homogenize data collection and description of procedures for scientific and educational purposes. The Medina-CTO classification replicates the classical three digits in Medina classification for bifurcations, representing the proximal main vessel, distal main vessel, and side branch, respectively. Each digit can take a value of 1 if it concerns atherosclerosis and is anatomically stenosed, or 0 if it is not. In addition, the occluded segment(s) of the bifurcation are noted by a subscript, which describes key interventional features of the cap: t (tapered), b (blunt), or a (ambiguous). This approach results in 56 basic categories that can be grouped by means of different elements, depending on the specific needs of each study. Medina-CTO classification, consisting of adding a subscript describing the basic cap characteristics to the totally occluded segment(s) of the standard Medina triplet, might be a useful methodological tool to standardize percutaneous intervention of bifurcational CTO lesions, with interesting scientific and educational applications.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Angiografia Coronária/métodos , Doença Crônica , Resultado do Tratamento
12.
13.
Nat Rev Cardiol ; 19(10): 684-703, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35449407

RESUMO

Since optical coherence tomography (OCT) was first performed in humans two decades ago, this imaging modality has been widely adopted in research on coronary atherosclerosis and adopted clinically for the optimization of percutaneous coronary intervention. In the past 10 years, substantial advances have been made in the understanding of in vivo vascular biology using OCT. Identification by OCT of culprit plaque pathology could potentially lead to a major shift in the management of patients with acute coronary syndromes. Detection by OCT of healed coronary plaque has been important in our understanding of the mechanisms involved in plaque destabilization and healing with the rapid progression of atherosclerosis. Accurate detection by OCT of sequelae from percutaneous coronary interventions that might be missed by angiography could improve clinical outcomes. In addition, OCT has become an essential diagnostic modality for myocardial infarction with non-obstructive coronary arteries. Insight into neoatherosclerosis from OCT could improve our understanding of the mechanisms of very late stent thrombosis. The appropriate use of OCT depends on accurate interpretation and understanding of the clinical significance of OCT findings. In this Review, we summarize the state of the art in cardiac OCT and facilitate the uniform use of this modality in coronary atherosclerosis. Contributions have been made by clinicians and investigators worldwide with extensive experience in OCT, with the aim that this document will serve as a standard reference for future research and clinical application.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Placa Aterosclerótica , Aterosclerose/patologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Infarto do Miocárdio/complicações , Placa Aterosclerótica/patologia , Stents , Tomografia de Coerência Óptica/métodos
14.
Open Heart ; 9(1)2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35410913

RESUMO

OBJECTIVE: This study aimed to evaluate the prognostic value of hyperemic microvascular resistance (HMR) and its relationship with hyperemic stenosis resistance (HSR) index and fractional flow reserve (FFR) in stable coronary artery disease. METHODS: This is a substudy of the DEFINE-FLOW cohort (NCT02328820), which evaluated the prognosis of lesions (n=456) after combined FFR and coronary flow reserve (CFR) assessment in a prospective, non-blinded, non-randomised, multicentre study in 12 centres in Europe and Japan. Participants (n=430) were evaluated by wire-based measurement of coronary pressure, flow and vascular resistance (ComboWire XT, Phillips Volcano, San Diego, California, USA). RESULTS: Mean FFR and CFR were 0.82±0.10 and 2.2±0.6, respectively. When divided according to FFR and CFR thresholds (above and below 0.80 and 2.0, respectively), HMR was highest in lesions with FFR>0.80 and CFR<2.0 (n=99) compared with lesions with FFR≤0.80 and CFR≥2.0 (n=68) (2.92±1.2 vs 1.91±0.64 mm Hg/cm/s, p<0.001). The FFR value was proportional to the ratio between HMR and the HMR+HSR (total resistance), 95% limits of agreement (-0.032; 0.019), bias (-0.003±0.02) and correlation (r2=0.98, p<0.0001). Cox regression model using HMR as continuous parameter for target vessel failure showed an HR of 1.51, 95% CI (0.9 to 2.4), p=0.10. CONCLUSIONS: Increased HMR was not associated with a higher rate of adverse clinical events, in this population of mainly stable patients. FFR can be equally well expressed as HMR/HMR+HSR, thereby providing an alternative conceptual formulation linking epicardial severity with microvascular resistance. TRIAL REGISTRATION NUMBER: NCT02328820.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença
15.
Artigo em Inglês | MEDLINE | ID: mdl-35041147

RESUMO

The physiological mechanisms of quantitative flow ratio and fractional flow reserve disagreement are not fully understood. We aimed to characterize the coronary flow and resistance profile of intermediate stenosed epicardial coronary arteries with concordant and discordant FFR and QFR. Post-hoc analysis of the DEFINE-FLOW study. Anatomical and Doppler-derived physiological parameters were compared for lesions with FFR+QFR- (n = 18) vs. FFR+QFR+ (n = 43) and for FFR-QFR+ (n = 34) vs. FFR-QFR- (n = 139). The association of QFR results with the two-year rate of target vessel failure was assessed in the proportion of vessels (n = 195) that did not undergo revascularization. Coronary flow reserve was higher [2.3 (IQR: 2.1-2.7) vs. 1.9 (IQR: 1.5-2.4)], hyperemic microvascular resistance lower [1.72 (IQR: 1.48-2.31) vs. 2.26 (IQR: 1.79-2.87)] and anatomical lesion severity less severe [% diameter stenosis 45.5 (IQR: 41.5-52.5) vs. 58.5 (IQR: 53.1-64.0)] for FFR+QFR- lesions compared with FFR+QFR+ lesions. In comparison of FFR-QFR+ vs. FFR-QFR- lesions, lesion severity was more severe [% diameter stenosis 55.2 (IQR: 51.7-61.3) vs. 43.4 (IQR: 35.0-50.6)] while coronary flow reserve [2.2 (IQR: 1.9-2.9) vs. 2.2 (IQR: 1.9-2.6)] and hyperemic microvascular resistance [2.34 (IQR: 1.85-2.81) vs. 2.57 (IQR: 2.01-3.22)] did not differ. The agreement and diagnostic performance of FFR using hyperemic stenosis resistance (> 0.80) as reference standard was higher compared with QFR and coronary flow reserve. Disagreement between FFR and QFR is partly explained by physiological and anatomical factors. Clinical Trials Registration https://www.clinicaltrials.gov ; Unique identifier: NCT01813435. Changes in central physiological and anatomical parameters according to FFR and QFR match/mismatch quadrants.

16.
Clin Transplant ; 36(1): e14488, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34747048

RESUMO

Cardiac allograft vasculopathy (CAV) remains a leading cause of long-term mortality after heart transplantation. Both preventive measures and treatment options are limited. This study aimed to evaluate the short-term effects of high-intensity interval training (HIT) on CAV in de novo heart transplant (HTx) recipients as assessed by optical coherence tomography (OCT). The study population was a subgroup of the 81-patient HITTS study in which HTx recipients were randomized to HIT or moderate intensity continuous training (MICT) for nine consecutive months. OCT images from baseline and 12 months were compared to assess CAV progression. The primary endpoint was defined as the change in the mean intima area. Paired OCT data were available for 56 patients (n = 23 in the HIT group and n = 33 in the MICT group). The intima area in the entire study population increased by 25% [from 1.8±1.4 mm2 to 2.3±2.0 mm2 , P < .05]. The change was twofold higher in the MICT group (.6±1.2 mm2 ) than in the HIT group (.3±.6 mm2 ). However, the treatment effect of HIT was not significant (treatment effect = -.3 mm2 , 95% CI [-.825 to .2 mm2 ] P = .29). These results suggest that early initiation of HIT compared with MICT does not attenuate CAV progression in de novo HTx recipients.


Assuntos
Transplante de Coração , Treinamento Intervalado de Alta Intensidade , Aloenxertos , Transplante de Coração/efeitos adversos , Humanos , Tomografia de Coerência Óptica
17.
EuroIntervention ; 17(15): 1252-1259, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-34219667

RESUMO

BACKGROUND: Quantitative flow ratio (QFR) is a tool for physiological lesion assessment based on invasive coronary angiography. AIMS: We aimed to assess the reproducibility of QFR computed from the same angiograms as assessed by multiple observers from different, international sites. METHODS: We included 50 patients previously enrolled in dedicated QFR studies. QFR was computed twice, one month apart by five blinded observers. The main analysis was the coefficient of variation (CV) as a measure of intra- and inter-observer reproducibility. Key secondary analysis was the identification of clinical and procedural characteristics predicting reproducibility. RESULTS: The intra-observer CV ranged from 2.3% (1.5-2.8) to 10.2% (6.6-12.0) among the observers. The inter-observer CV was 9.4% (8.0-10.5). The QFR observer, low angiographic quality, and low fractional flow reserve (FFR) were independent predictors of a large absolute difference between repeated QFR measurements defined as a difference larger than the median difference (>0.03). CONCLUSIONS: The inter- and intra-observer reproducibility for QFR computed from the same angiograms ranged from high to poor among multiple observers from different sites with an average agreement of 0.01±0.08 for repeated measurements. The reproducibility was dependent on the observer, angiographic quality and the coronary artery stenosis severity as assessed by FFR.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
18.
Circ Genom Precis Med ; 14(3): e003298, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34032468

RESUMO

BACKGROUND: Polygenic risk scores (PRSs) are associated with coronary artery disease (CAD), but the clinical potential of using PRSs at the single-patient level for risk stratification has yet to be established. We investigated whether adding a PRS to clinical risk factors (CRFs) improves risk stratification in patients referred to coronary computed tomography angiography on a suspicion of obstructive CAD. METHODS: In this prespecified diagnostic substudy of the Dan-NICAD trial (Danish study of Non-Invasive testing in Coronary Artery Disease), we included 1617 consecutive patients with stable chest symptoms and no history of CAD referred for coronary computed tomography angiography. CRFs used for risk stratification were age, sex, symptoms, prior or active smoking, antihypertensive treatment, lipid-lowering treatment, and diabetes. In addition, patients were genotyped, and their PRSs were calculated. All patients underwent coronary computed tomography angiography. Patients with a suspected ≥50% stenosis also underwent invasive coronary angiography with fractional flow reserve. A combined end point of obstructive CAD was defined as a visual invasive coronary angiography stenosis >90%, fractional flow reserve <0.80, or a quantitative coronary analysis stenosis >50% if fractional flow reserve measurements were not feasible. RESULTS: The PRS was associated with obstructive CAD independent of CRFs (adjusted odds ratio, 1.8 [95% CI, 1.5-2.2] per SD). The PRS had an area under the curve of 0.63 (0.59-0.68), which was similar to that for age and sex. Combining the PRS with CRFs led to a CRF+PRS model with area under the curve of 0.75 (0.71-0.79), which was 0.04 more than the CRF model (P=0.0029). By using pretest probability (pretest probability) cutoffs at 5% and 15%, a net reclassification improvement of 15.8% (P=3.1×10-4) was obtained, with a down-classification of risk in 24% of patients (211 of 862) in whom the pretest probability was 5% to 15% based on CRFs alone. CONCLUSIONS: Adding a PRS improved risk stratification of obstructive CAD beyond CRFs, suggesting a modest clinical potential of using PRSs to guide diagnostic testing in the contemporary clinical setting. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02264717.


Assuntos
Dor no Peito , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Estenose Coronária , Dor no Peito/diagnóstico por imagem , Dor no Peito/genética , Dor no Peito/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/genética , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/genética , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
19.
Eur Heart J ; 42(27): 2695-2707, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-33822922

RESUMO

Percutaneous coronary intervention (PCI) guided by coronary physiology provides symptomatic benefit and improves patient outcomes. Nevertheless, over one-fourth of patients still experience recurrent angina or major adverse cardiac events following the index procedure. Coronary angiography, the current workhorse for evaluating PCI efficacy, has limited ability to identify suboptimal PCI results. Accumulating evidence supports the usefulness of immediate post-procedural functional assessment. This review discusses the incidence and possible mechanisms behind a suboptimal physiology immediately after PCI. Furthermore, we summarize the current evidence base supporting the usefulness of immediate post-PCI functional assessment for evaluating PCI effectiveness, guiding PCI optimization, and predicting clinical outcomes. Multiple observational studies and post hoc analyses of datasets from randomized trials demonstrated that higher post-PCI functional results are associated with better clinical outcomes as well as a reduced rate of residual angina and repeat revascularization. As such, post-PCI functional assessment is anticipated to impact patient management, secondary prevention, and resource utilization. Pre-PCI physiological guidance has been shown to improve clinical outcomes and reduce health care costs. Whether similar benefits can be achieved using post-PCI physiological assessment requires evaluation in randomized clinical outcome trials.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angina Pectoris , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Custos de Cuidados de Saúde , Humanos , Resultado do Tratamento
20.
Cardiology ; 146(4): 409-418, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33849035

RESUMO

BACKGROUND: In the treatment of left main coronary artery (LMCA) disease, patients' age may affect the clinical outcome after percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). This study stratified the clinical outcome according to the age of patients treated for LMCA stenosis with PCI or CABG in the Nordic-Baltic-British Left Main Revascularization (NOBLE) study. METHODS: Patients with LMCA disease were enrolled in 36 centers in northern Europe and randomized 1:1 to treatment by PCI or CABG. Eligible patients had stable angina pectoris, unstable angina pectoris, or non-ST elevation myocardial infarction. The primary endpoint was major adverse cardiac or cerebrovascular events (MACCEs), a composite of all-cause mortality, nonprocedural myocardial infarction, any repeat coronary revascularization, and stroke. Age-stratified analysis was performed for the groups younger and older than 67 years and for patients older than 80 years. RESULTS: For patients ≥67 years, the 5-year MACCEs were 35.7 versus 22.3% (hazard ratio [HR] 1.72 [95% confidence interval [CI] 1.27-2.33], p = 0.0004) for PCI versus CABG. The difference in MACCEs was driven by more myocardial infarctions (10.8 vs. 3.8% HR 3.01 [95% CI 1.52-5.96], p = 0.0009) and more repeat revascularizations (19.5 vs. 10.0% HR 2.01 [95% CI 1.29-3.12], p = 0.002). In patients younger than 67 years, MACCE was 20.5 versus 15.3% (HR 1.38 [95% CI 0.93-2.06], p = 0.11 for PCI versus CABG. All-cause mortality was similar after PCI and CABG in both age-groups. On multivariate analysis, age was a predictor of MACCE, along with PCI, diabetes, and SYNTAX score. CONCLUSIONS: As the overall NOBLE results show revascularization of LMCA disease, age of 67 years or older was associated with lower 5-year MACCE after CABG compared to PCI. Clinical outcomes were not significantly different in the subgroup younger than 67 years, although no significant interaction was present between age and treatment. Mortality was similar for all subgroups (ClinicalTrials.gov identifier: NCT01496651).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Idoso , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/cirurgia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...